The following information is provided as a guide only and is read at the reader's discretion. While MDSA Pty Ltd believe that the information is correct and true at the time of publishing, any and all information is published without warranty, and with the expectation that the reader will make their own enquires to confirm that such information is suitable for their purposes.

CONTACT THIS SUPPLIER TO FIND OUT MORE

Clinical Data

Evaluation of Variable Mandibular Advancement Appliance for Treatment of Snoring and Sleep Apnea*
(Chest. 1999;1 16:1511-1518.) @ 1999 American College of Chest Physicians

JEFFREY PANCER, DDS; SALEM AL-FAIFI, MD; MOHAMED AL-FAIFI, MD AND VICTOR HOFFSTEIN, PhD, MD, FCCP

* From the Department of Medicine, Respiratory Division, St. Michael's Hospital, University of Toronto, Ontario, Canada.

Correspondence to: Victor Hoffstein, PhD, MD, FCCP, St. Michael's Hospital, 30 Bond St, Toronto, Ontario, Canada M 5 B I W8; e-mail: victor.hoffstein@utoronto.ca

Objective: To evaluate an adjustable mandibular positioning appliance for treatment of snoring and sleep apnea.

Methods: One hundred thirty-four patients with baseline apnea/hypopnea index (AHI) of 37 ± 28 events/h (mean ± SD) received the appliance. The efficacy of the appliance was assessed by the following investigations, performed at baseline and with the appliance: polysomnography, Epworth sleepiness scale, bedpartners' assessment of snoring severity, patients' assessment of side effects, and overall satisfaction.

Results: Thirteen patients were lost to follow-up. Additional 46 patients had no follow-up polysomnography, but answered the questionnaires. A total of 75 patients had polysomnography at baseline and with the appliance. We found a significant reduction in AHI from 44 ± 28 events/h to 1 2 ± 1 5 events/h (p < 0.0005) and a reduction in the arousal index from 37 ± 27 events/h to 1 6 ± 1 3 events/h (p < 0.05). Epworth scores fell from II ± 5 to 7 ± 3 (p < 0.0005). Bedpartners' assessment revealed marked improvement in snoring. For example, at baseline 96% of patients were judged to snore loudly "often" or "always" by their bedpartners, whereas only 2% were judged so while using dental appliance. The most frequent side effect was teeth discomfort, present "sometimes" or often" in up to 32% of patients. Follow-up clinical assessment in 1 21 patients conducted on the average 350 days after the insertion of the appliance revealed that 86% of patients continued to use the appliance nightly; 60% were very satisfied with the appliance, 27% were moderately satisfied, 11% were moderately dissatisfied, and 2% were very dissatisfied.

Conclusion: We conclude that the adjustable mandibular positioning appliance is an effective treatment alternative for some patients with snoring and sleep apnoea.