Kaixin Bladder Scanner | Handheld BVT02
This handheld bladder scanner is a portable, non-invasive ultrasound device designed to accurately measure bladder volume at the point of care. Featuring a 3.5″ colour LCD, fast scan time, and intuitive operation, it supports the assessment of urinary retention, postoperative urinary retention (POUR), and helps reduce unnecessary catheterisation and catheter-associated urinary tract infections (CAUTIs).
Ideal for use in hospitals, emergency departments, surgical wards, aged care facilities, rehabilitation centres, and outpatient clinics, this mobile bladder scanner improves workflow efficiency while maintaining patient comfort and safety.
Power Supply: AC 100–240V, 50–60Hz
Input: DC 12V, 3.0A
Battery Operation: Approx. 4 hours continuous use (Li-battery)
Main Unit Dimensions: Approx. 90 mm (L) × 98 mm (W) × 25 mm (H)
Weight: Approx. 750 g (including probe and battery)
Outer Packaging Dimensions: 365 mm × 255 mm × 270 mm
Probe Frequency: 2.5 MHz
Volume Calculation Method: 12 reference planes at 15° intervals
Volume Rendering Resolution: 1 mL
Measurement Range: 20 mL – 999 mL
Measurement Accuracy:
20 mL – 99 mL: ±15 mL deviation
100 mL – 999 mL: ±15% deviation
To contact Zone Medical about Kaixin Bladder Scanner | Handheld BVT02 use Get a quote.
This handheld bladder scanner is a portable, non-invasive ultrasound device designed to accurately measure bladder volume at the point of care. Featuring a 3.5″ colour LCD, fast scan time, and intuitive operation, it supports the assessment of urinary retention, postoperative urinary retention (POUR), and helps reduce unnecessary catheterisation and catheter-associated urinary tract infections (CAUTIs).
Ideal for use in hospitals, emergency departments, surgical wards, aged care facilities, rehabilitation centres, and outpatient clinics, this mobile bladder scanner improves workflow efficiency while maintaining patient comfort and safety.
Power Supply: AC 100–240V, 50–60Hz
Input: DC 12V, 3.0A
Battery Operation: Approx. 4 hours continuous use (Li-battery)
Main Unit Dimensions: Approx. 90 mm (L) × 98 mm (W) × 25 mm (H)
Weight: Approx. 750 g (including probe and battery)
Outer Packaging Dimensions: 365 mm × 255 mm × 270 mm
Probe Frequency: 2.5 MHz
Volume Calculation Method: 12 reference planes at 15° intervals
Volume Rendering Resolution: 1 mL
Measurement Range: 20 mL – 999 mL
Measurement Accuracy:
20 mL – 99 mL: ±15 mL deviation
100 mL – 999 mL: ±15% deviation
To contact Zone Medical about Kaixin Bladder Scanner | Handheld BVT02 use Get a quote.