The Benchtop Freeze Dryer is a compact lyophilisation unit, ideal for laboratories with limited space, designed for the efficient freeze drying of light sample loads.
Description
Compact benchtop design with advanced touch-screen control for efficient, high-quality sample lyophilisation.
Key Features
- Upright stainless steel collector coil with ice capacity ranging from 2.5 L to 8 L before defrosting.
- Three temperature configurations available: -50°C for aqueous samples, -84°C for a wide range of solvents, and -105°C for dilute ethanol and methanol mixtures.
- PTFE-coated collector coil and chamber option for corrosive samples.
- Compact benchtop footprint with brushed stainless steel and powder-coated steel exterior.
- 5" full-colour capacitive touchscreen interface with Lyo-Works™ OS, providing real-time display of collector temperature, vacuum levels, and optional End-Zone™ end point detection system.
- Data logging, exportable via USB or Ethernet.
- Programmable alerts and maintenance reminders (e.g., vacuum pump oil change, refrigeration cleaning, total operating hours).
- Hot gas defrost with auto shut off at +60°C.
- Security lock-out for program and system parameter changes.
- Moisture sensors and vacuum control valves for safety and process control.
- Side-mounted USB and quick-disconnect drain hose; rear-mounted Ethernet and electrical connections.
- Automatic or manual start-up modes for collector cool-down and vacuum pull-down.
- Restart capability after brief power outages.
Capacity & Dimensions
- Collector coil holds from 2.5 L to 8 L of ice (depending on model).
- 3/4" thick acrylic collector lid with neoprene gasket and 3" diameter port for drying accessory connection.
- Vacuum connection: 3/4" OD, with 50" of 3/4" ID vacuum hose and two clamps.
Required Accessories (not included)
- Vacuum pump with at least 98 L/min displacement, 0.02 mBar ultimate pressure, and fittings for 3/4" ID vacuum hose.
- Freeze dry glassware, small tray dryer, or other suitable drying accessory.
Additional Options
- PTFE-coated collectors for enhanced chemical resistance.
- Region-specific electrical plug configurations.
- Multiple supported languages for the interface.
Safety & Maintenance
- Programmable alerts for maintenance and safe operation.
- Moisture sensors prevent operation when water is detected in drain line.
- Automatic system restart after power outages under 5 minutes, with safety checks for temperatures.
- Level-specific lockouts for added security.
Control & Connectivity
- Interface supports multiple languages.
- USB and Ethernet connectivity for monitoring and data export.
- Configurable alerts via Ethernet to email addresses.
To contact Thermo Fisher Scientific Australia Pty Ltd about FreeZone™ 4.5 L -50°C Benchtop Freeze Dryer, 230 V Model use Get a quote.
Key Features
- Upright stainless steel collector coil with ice capacity ranging from 2.5 L to 8 L before defrosting.
- Three temperature configurations available: -50°C for aqueous samples, -84°C for a wide range of solvents, and -105°C for dilute ethanol and methanol mixtures.
- PTFE-coated collector coil and chamber option for corrosive samples.
- Compact benchtop footprint with brushed stainless steel and powder-coated steel exterior.
- 5" full-colour capacitive touchscreen interface with Lyo-Works™ OS, providing real-time display of collector temperature, vacuum levels, and optional End-Zone™ end point detection system.
- Data logging, exportable via USB or Ethernet.
- Programmable alerts and maintenance reminders (e.g., vacuum pump oil change, refrigeration cleaning, total operating hours).
- Hot gas defrost with auto shut off at +60°C.
- Security lock-out for program and system parameter changes.
- Moisture sensors and vacuum control valves for safety and process control.
- Side-mounted USB and quick-disconnect drain hose; rear-mounted Ethernet and electrical connections.
- Automatic or manual start-up modes for collector cool-down and vacuum pull-down.
- Restart capability after brief power outages.
Capacity & Dimensions
- Collector coil holds from 2.5 L to 8 L of ice (depending on model).
- 3/4" thick acrylic collector lid with neoprene gasket and 3" diameter port for drying accessory connection.
- Vacuum connection: 3/4" OD, with 50" of 3/4" ID vacuum hose and two clamps.
Required Accessories (not included)
- Vacuum pump with at least 98 L/min displacement, 0.02 mBar ultimate pressure, and fittings for 3/4" ID vacuum hose.
- Freeze dry glassware, small tray dryer, or other suitable drying accessory.
Additional Options
- PTFE-coated collectors for enhanced chemical resistance.
- Region-specific electrical plug configurations.
- Multiple supported languages for the interface.
Safety & Maintenance
- Programmable alerts for maintenance and safe operation.
- Moisture sensors prevent operation when water is detected in drain line.
- Automatic system restart after power outages under 5 minutes, with safety checks for temperatures.
- Level-specific lockouts for added security.
Control & Connectivity
- Interface supports multiple languages.
- USB and Ethernet connectivity for monitoring and data export.
- Configurable alerts via Ethernet to email addresses.
To contact Thermo Fisher Scientific Australia Pty Ltd about FreeZone™ 4.5 L -50°C Benchtop Freeze Dryer, 230 V Model use Get a quote.
Credit score not impacted
How much do you need?
Just an estimate is fine.
Weekly repayments (rates from 6.85% p.a)
Calculating...
Calculating...
Enquire about this product & finance options.
Get a quote
Let Thermo Fisher Scientific Australia Pty Ltd provide you with a quote
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Supplier
Location: Scoresby, VIC
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. Thermo Fisher Scientific Australia Pty Ltd are also proudly displaying these credentials:
Location:
Scoresby ,
VIC
Joined:
Sep 2026
Level:
Premium Storefront
Verified:
Credit score not impacted
How much do you need?
Just an estimate is fine.
Weekly repayments (rates from 6.85% p.a)
Calculating...
Calculating...
Enquire about this product & finance options.
Is this your product?
Manage products / company details |
Report this product
Recommended categories
More from this supplier
Ultra Low Temperature Chest Freezer | CxF Series -86°C
Digital Hot Plate | RT2
Vortex Mixer | MaxiMix
Orbital Shaker | Digital Tube Rocker
CO2 Incubator | Heracell Vios 160i CR
IntelliStack Incubator Shaker, Single Unit Down swing door
Solaris 6000 Incubated and Refrigerated Stackable Shaker
General Protocol Microbiological Incubator 117 L
Large-Capacity Reach-In CO2 Incubator, 821 L, Polished Stainless Steel
Steri-Cycle CO2 Incubator, 184 L, Polished Stainless Steel
Vios™ iDx 255 L CO2 Incubators 230 V
Vios™ iDx 165 L CO2 Incubator Electropolished Stainless Steel
BB 150 Direct Heat CO2 Incubator
Herasafe 2025 Class II Biological Safety Cabinet, Cross Beam UV function 1300 mm
C Series Refrigerated Centrifuges C1TR: General Use
S2TR Refrigerated General Purpose Centrifuge IVD-MD
S2T Ventilated General Purpose Centrifuge IVD-MD
S4T Ventilated Centrifuges IVD-MD
VersaCool™ Refrigerated Circulating Bath, -20° to +150°C
ARCTIC A10 Refrigerated Circulators 6 L
You might also like these
Contact Thermo Fisher Scientific Australia Pty Ltd
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
Let Thermo Fisher Scientific Australia Pty Ltd know you found them on MedicalSearch so they can best assist you!
1300 735 295
Are you a Laboratory Freeze Dryer supplier?
Reach valuable medical buyers in minutes
Promote key products & content
Drive cost effective & measurable sales
learn more