GENESYS™ 40/50 Vis/UV-Vis Spectrophotometer ...
Perform routine measurements for quality control or teaching in the chemistry classroom with rugged Thermo Scientific™ GENESYS™ 50 UV-Visible and GENESYS 40 Vis Spectrophotometers. Offered in a single cell configuration, these instruments are designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and optional Wi-Fi networking make the GENESYS 50 UV-Vis or GENESYS 40 Vis Spectrophotometer the ideal choice for daily sampling purposes.
The GENESYS 50 is a dual beam UV-Vis spectrophotometer in a single-cell configuration that meets all of the specifications for critical quality control applications and precise chemical measurements. The GENESYS 40 Dual Beam Vis Spectrophotometer is a visible spectral region version in this instrumental class. Both feature data resolution from 0.2 nm to 5 nm.
Features:
?Designed for:?
Specification | Details |
|---|---|
Baseline Flatness | ±0.002 A |
Compartments | Accessible from top, front or side |
Cell Compatibility | Able to accommodate cells up to 100 mm cells |
Test Tube Accessory | Available accessory for test tubes up to 25 mm diameter and 150 mm height |
Sample Compartment Liner | Removable, washable sample compartment liner with magnetic placement and hold-down |
Connections | Single USB-A; Duplex USB-A |
Data Export | Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor available |
Printing | Print via USB, Ethernet or Wi-Fi USB adaptor available |
Dimensions (L × W × H) | 35.5 × 38.5 × 19.5 cm |
Drift | <0.0005 A/hr. (at 500 nm after 1 hour warmup) |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
For Use With (Application) | Sample Concentration |
Includes | GENESYS 50 Spec + UK Power cord |
Keypad | Touchscreen |
Lamp Life | >5 years typical, 3 years guaranteed |
Noise | =0.00020 A at 0 A at 260 and 500 nm; =0.00030 A at 1 A at 260 and 500 nm; =0.00040 A at 2 A at 260 and 500 nm |
Optical Design | Dual Beam |
Photometric Accuracy | ±0.002 A at 0.5 A; ±0.004 A at 1.0 A; ±0.008 A at 2.0 A |
Photometric Display | -3 A to +5 A |
Photometric Range | -2 A to +3.5 A |
Photometric Repeatability | ±0.001 A at 1 A measured at 1.0 A at 546 nm |
Printer Included | Snap-on printer available |
Scan Speed | Slow, medium and fast — up to 1600 nm/min. |
Stray Light | <1.0%T at 198 nm (KCl); <0.05%T at 220 nm (NaI); <0.03%T at 340 nm (NaNO2) |
Warranty | 2 yrs std + 1 yr ext upon reg |
Wavelength Accuracy | ±0.5 nm |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Repeatability | <±0.2 nm |
Weight (Metric) | 7.5 kg |
Detector Type | Dual Silicon Photodiodes |
Display | 7 in. High Definition Color Touchscreen, Fixed, 800 × 1280 pixels |
Spectral Bandwidth | 2 nm |
Wavelength Range | 190 to 1100 nm |
Unit Size | Each |
To contact Thermo Fisher Scientific Australia Pty Ltd about GENESYS™ 40/50 Vis/UV-Vis Spectrophotometer | 50 Spec+UK Power cord use Get a quote.
Perform routine measurements for quality control or teaching in the chemistry classroom with rugged Thermo Scientific™ GENESYS™ 50 UV-Visible and GENESYS 40 Vis Spectrophotometers. Offered in a single cell configuration, these instruments are designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and optional Wi-Fi networking make the GENESYS 50 UV-Vis or GENESYS 40 Vis Spectrophotometer the ideal choice for daily sampling purposes.
The GENESYS 50 is a dual beam UV-Vis spectrophotometer in a single-cell configuration that meets all of the specifications for critical quality control applications and precise chemical measurements. The GENESYS 40 Dual Beam Vis Spectrophotometer is a visible spectral region version in this instrumental class. Both feature data resolution from 0.2 nm to 5 nm.
Features:
?Designed for:?
Specification | Details |
|---|---|
Baseline Flatness | ±0.002 A |
Compartments | Accessible from top, front or side |
Cell Compatibility | Able to accommodate cells up to 100 mm cells |
Test Tube Accessory | Available accessory for test tubes up to 25 mm diameter and 150 mm height |
Sample Compartment Liner | Removable, washable sample compartment liner with magnetic placement and hold-down |
Connections | Single USB-A; Duplex USB-A |
Data Export | Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor available |
Printing | Print via USB, Ethernet or Wi-Fi USB adaptor available |
Dimensions (L × W × H) | 35.5 × 38.5 × 19.5 cm |
Drift | <0.0005 A/hr. (at 500 nm after 1 hour warmup) |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
For Use With (Application) | Sample Concentration |
Includes | GENESYS 50 Spec + UK Power cord |
Keypad | Touchscreen |
Lamp Life | >5 years typical, 3 years guaranteed |
Noise | =0.00020 A at 0 A at 260 and 500 nm; =0.00030 A at 1 A at 260 and 500 nm; =0.00040 A at 2 A at 260 and 500 nm |
Optical Design | Dual Beam |
Photometric Accuracy | ±0.002 A at 0.5 A; ±0.004 A at 1.0 A; ±0.008 A at 2.0 A |
Photometric Display | -3 A to +5 A |
Photometric Range | -2 A to +3.5 A |
Photometric Repeatability | ±0.001 A at 1 A measured at 1.0 A at 546 nm |
Printer Included | Snap-on printer available |
Scan Speed | Slow, medium and fast — up to 1600 nm/min. |
Stray Light | <1.0%T at 198 nm (KCl); <0.05%T at 220 nm (NaI); <0.03%T at 340 nm (NaNO2) |
Warranty | 2 yrs std + 1 yr ext upon reg |
Wavelength Accuracy | ±0.5 nm |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Repeatability | <±0.2 nm |
Weight (Metric) | 7.5 kg |
Detector Type | Dual Silicon Photodiodes |
Display | 7 in. High Definition Color Touchscreen, Fixed, 800 × 1280 pixels |
Spectral Bandwidth | 2 nm |
Wavelength Range | 190 to 1100 nm |
Unit Size | Each |
To contact Thermo Fisher Scientific Australia Pty Ltd about GENESYS™ 40/50 Vis/UV-Vis Spectrophotometer | 50 Spec+UK Power cord use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product