Indicator Strips | 500/Box MDFCL2500
MediForce Plus Class 2 Chemical Indicators (500 pcs)
MediForce Plus Class 2 Chemical Indicator strips are designed for routine monitoring of steam penetration conditions in hollow load sterilisation cycles when used within the MediForce Plus Process Challenge Device (PCD).
Application: Hollow load monitoring (Air Removal & Steam Penetration) when used within a PCD.
For routine monitoring of dental and medical benchtop pre-vacuum (Class B) steam sterilisers.
When used in conjunction with the MediForce Plus Process Challenge Device (PCD), these strips assist in monitoring steam penetration conditions during routine steam sterilisation cycles.
Batch Monitoring: Provides visual confirmation of exposure to defined steam sterilisation parameters during routine monitoring cycles.
Note: Monitoring frequency should follow facility policy and applicable standards.
Technical Specifications:
Refill indicator strips (500 pcs) for use with Mediforce Plus PCD Device.
Intended for use in steam sterilisation cycles including: 134°C / 3.5 min and 121°C / 15 min.
Conforms to ISO 11140-1 (General requirements for chemical indicators).
ALWAYS FOLLOW THE DIRECTIONS FOR USE. Included in the ARTG: 485139
To contact Healthware Australia about Indicator Strips | 500/Box MDFCL2500 use Get a quote.
MediForce Plus Class 2 Chemical Indicators (500 pcs)
MediForce Plus Class 2 Chemical Indicator strips are designed for routine monitoring of steam penetration conditions in hollow load sterilisation cycles when used within the MediForce Plus Process Challenge Device (PCD).
Application: Hollow load monitoring (Air Removal & Steam Penetration) when used within a PCD.
For routine monitoring of dental and medical benchtop pre-vacuum (Class B) steam sterilisers.
When used in conjunction with the MediForce Plus Process Challenge Device (PCD), these strips assist in monitoring steam penetration conditions during routine steam sterilisation cycles.
Batch Monitoring: Provides visual confirmation of exposure to defined steam sterilisation parameters during routine monitoring cycles.
Note: Monitoring frequency should follow facility policy and applicable standards.
Technical Specifications:
Refill indicator strips (500 pcs) for use with Mediforce Plus PCD Device.
Intended for use in steam sterilisation cycles including: 134°C / 3.5 min and 121°C / 15 min.
Conforms to ISO 11140-1 (General requirements for chemical indicators).
ALWAYS FOLLOW THE DIRECTIONS FOR USE. Included in the ARTG: 485139