COSMED Metabolic Monitor | Q-NRG+
COSMED - Metabolic Monitor | Q-NRG+
Introducing the new generation of Metabolic Monitors for Indirect Calorimetry in Clinical and Critical Care Practice
Introduced by COSMED, worldwide leader in the design of metabolic systems for clinical and human performance applications, Q-NRG is the first Indirect Calorimeter specifically intended for the measurement of Resting Energy Expenditure (REE) in patients who are mechanically ventilated or spontaneously breathing and for healthy subjects.
Indirect calorimetry remains the Gold Standard in measuring energy expenditure in clinical settings, proven to have enormous advantages compared to Predictive Equations1. In fact, this measuring technology provides an individual and dynamic metabolic assessment based on the actual physical status of the subject rather than estimating it on anthropometric data.
Q-NRG is a unique product, the result of COSMED’s collaboration with world-class institutes in the field of nutrition support in intensive care units. Product concept and specifications have been designed together with the ICALIC Trial study group2. This collaboration made possible the development of an accurate metabolic system simple to use and at the same time able to solve all typical pitfalls of Indirect Calorimetry technology.
KEY FEATURES
Individual Metabolic Assessment Q-NRG uses the Gold Standard Indirect Calorimetry technique to measure metabolic parameters. The technique itself guarantees that the results reflect the metabolic alterations during illness and repeated measurements may correspond with disease progression or resolution4. QNRG is the ultimate tool to develop individual nutrition support plans and optimize them to prevent over/underfeeding, to reduce length of stay and, ultimately, to decrease costs in ICU.
Indirect Calorimetry, a Gold Standard Q-NRG is the result of more than 30 years of experience in the design of metabolic systems. The new calorimeter has been validated in-vitro by international multicentre study showing the greatest accuracy with excellent agreement vs. mass spectrometer measurements5,6.
Quick to operate, clean and maintain Q-NRG has been designed to reduce operations and measurement time. System does not require warm-up time nor user-assisted calibrations, all operations can be performed with a few taps on the screen and cleaning procedures are simplified thanks to rounded surfaces and single-use accessories.
Designed for Clinical Practice Q-NRG usability has been designed according to best clinical practice. An intuitive workflow supports the user through all operations with main instructions prompted along the procedures and test information always accessible. Designed to be portable, the device can be easily transported between rooms.
Latest Technologies in a Compact Device Q-NRG is a compact, lightweight, battery operating device. The 10” inches LCD touchscreen simplify access to all operations. Bluetooth, USB, RS-232 and LAN interfaces allow to connect the system to any hub (PC, printers, etc.).
Affordable Q-NRG has been designed to compete with conventional metabolic system, at a fraction of the cost.
One tool for many applications. Q-NRG provides all the flexibility for a variety of clinical settings, assessing different patient's conditions (mechanically ventilated or spontaneously breathing) and with different techniques (Canopy Hood and/or face masks), from adults to pediatric starting from 10 kg.
Standalone or PC based user mode. Q-NRG can be operated either via the integrated LCD touchscreen or controlled from a computer via OMNIA PC software (optional), with data transfer done wireless through Bluetooth® or USB interfaces.
VERSIONS
Q-NRG+
The New Generation Metabolic Monitor for Resting Energy Expenditure in ventilated patients and/or spontaneously breathing subjects
- Resting Energy Expenditure in ventilated patients or spontaneously breathing subjects
- Full Metabolic Assessment (REE, VO2, VCO2, VE, RQ etc.)
- Compact, lightweight, battery and main operated
- Test subjects with Ventilator, Canopy or Face Mask
- Immediate, simple set-up and system operation
- Designed for easy cleaning and maintenance
- No daily gas calibration required
Q-NRG
The New Generation Metabolic Monitor for Resting Energy Expenditure in spontaneously breathing subjects
- Resting Energy Expenditure in spontaneously breathing subjects
- Full Metabolic Assessment (REE, VO2, VCO2, VE, RQ etc.)
- Compact, lightweight, battery and main operated
- Test subjects with Canopy or (optional) Face Mask
- Immediate, simple set-up and system operation
- Designed for easy cleaning and maintenance
- No daily gas calibration required
TEST MODES
Vent (Mechanically assisted patients)
- Measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), together with other ventilatory parameters, and metabolism substrate utilization (%FAT, %PRO, %CHO).
- Ventilated patients (>age 10).
- Disposable PNT flowmeter (Flow-REE) inserted at the patient’s circuit
- All parts are single patient, no need for cleaning and disinfecting
- Independent from type of ventilator in use
[Available standard for Q-NRG+ only]
Canopy (Spontaneously breathing subjects)
- Measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), together with other ventilatory parameters, and metabolism substrate utilization (%FAT, %PRO, %CHO).
- Spontaneously breathing subjects (>age 6).
- Dilution technique using bubble canopy hood (available either adult or pediatric).
- Consumables: Canopy veil, antibacterial filters and corrugated tube
- Integrated canopy blower pump inside the unit (selectable flow rate with Q-NRG monitor).
[Available standard for Q-NRG and as an option for Q-NRG+]
Mask (Spontaneously breathing subjects)
- Measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), together with other ventilatory parameters, and metabolism substrate utilization (%FAT, %PRO, %CHO).
- Spontaneously breathing subjects (>age 6).
- External multi-use turbine flowmeter
- Multi-use silicone face masks with headgear for comfortable leak-free measurements
- 5 mask sizes (3 Adult and 2 Pediatric)
- Easy to clean and sterilize
[Available as an option for Q-NRG+ and Q-NRG]
TECH SPECS
| HARDWARE | |
|---|---|
| O2 gas analyser | Galvanic Fuel Cell (GFC) |
| CO2 gas analyser | Digital NDIR |
| Flowmeter - Vent | Disposable Pneumotach (Flow-REE) |
| Flowmeter - Canopy/Mask | Bidirectional digital turbine |
| Display | 10.1” Transmissive TFT LCD, 1024x600, 65k colors, capacitive touch screen |
| Battery Power | Battery: Li-Ion “smart”(3 hours autonomy) Mains: 100V-240V ±10%; 50/60Hz, 100-130 VA |
| Wireless connectivity | Bluetooth (2.1 + EDR Class II - Range 10 m line-of-sight) |
| Wired connectivity | 1 USB-device (5 kV galvanic insulated), 2 x USB Host, RS-232 (5 kV galvanic insulated), LAN (5 kV galvanic insulated) |
| Electrical requirements | 100-240V ± 10% 50/60 Hz |
| SOFTWARE (OPTIONAL) | |
| Software Interface | OMNIA |
| OS Compatibility | Windows 7, 8, 10 |
| Languages | Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Turkish, Russian, Chinese (Traditional & Simplifi ed), Korean, Romanian, Polish, Czech, Norwegian, Hebrew (interpretation only) |
To contact COSMED about COSMED Metabolic Monitor | Q-NRG+ use Get a quote.
Introduced by COSMED, worldwide leader in the design of metabolic systems for clinical and human performance applications, Q-NRG is the first Indirect Calorimeter specifically intended for the measurement of Resting Energy Expenditure (REE) in patients who are mechanically ventilated or spontaneously breathing and for healthy subjects.
Indirect calorimetry remains the Gold Standard in measuring energy expenditure in clinical settings, proven to have enormous advantages compared to Predictive Equations1. In fact, this measuring technology provides an individual and dynamic metabolic assessment based on the actual physical status of the subject rather than estimating it on anthropometric data.
Q-NRG is a unique product, the result of COSMED’s collaboration with world-class institutes in the field of nutrition support in intensive care units. Product concept and specifications have been designed together with the ICALIC Trial study group2. This collaboration made possible the development of an accurate metabolic system simple to use and at the same time able to solve all typical pitfalls of Indirect Calorimetry technology.
KEY FEATURES
Individual Metabolic Assessment Q-NRG uses the Gold Standard Indirect Calorimetry technique to measure metabolic parameters. The technique itself guarantees that the results reflect the metabolic alterations during illness and repeated measurements may correspond with disease progression or resolution4. QNRG is the ultimate tool to develop individual nutrition support plans and optimize them to prevent over/underfeeding, to reduce length of stay and, ultimately, to decrease costs in ICU.
Indirect Calorimetry, a Gold Standard Q-NRG is the result of more than 30 years of experience in the design of metabolic systems. The new calorimeter has been validated in-vitro by international multicentre study showing the greatest accuracy with excellent agreement vs. mass spectrometer measurements5,6.
Quick to operate, clean and maintain Q-NRG has been designed to reduce operations and measurement time. System does not require warm-up time nor user-assisted calibrations, all operations can be performed with a few taps on the screen and cleaning procedures are simplified thanks to rounded surfaces and single-use accessories.
Designed for Clinical Practice Q-NRG usability has been designed according to best clinical practice. An intuitive workflow supports the user through all operations with main instructions prompted along the procedures and test information always accessible. Designed to be portable, the device can be easily transported between rooms.
Latest Technologies in a Compact Device Q-NRG is a compact, lightweight, battery operating device. The 10” inches LCD touchscreen simplify access to all operations. Bluetooth, USB, RS-232 and LAN interfaces allow to connect the system to any hub (PC, printers, etc.).
Affordable Q-NRG has been designed to compete with conventional metabolic system, at a fraction of the cost.
One tool for many applications. Q-NRG provides all the flexibility for a variety of clinical settings, assessing different patient's conditions (mechanically ventilated or spontaneously breathing) and with different techniques (Canopy Hood and/or face masks), from adults to pediatric starting from 10 kg.
Standalone or PC based user mode. Q-NRG can be operated either via the integrated LCD touchscreen or controlled from a computer via OMNIA PC software (optional), with data transfer done wireless through Bluetooth® or USB interfaces.
VERSIONS
Q-NRG+
The New Generation Metabolic Monitor for Resting Energy Expenditure in ventilated patients and/or spontaneously breathing subjects
- Resting Energy Expenditure in ventilated patients or spontaneously breathing subjects
- Full Metabolic Assessment (REE, VO2, VCO2, VE, RQ etc.)
- Compact, lightweight, battery and main operated
- Test subjects with Ventilator, Canopy or Face Mask
- Immediate, simple set-up and system operation
- Designed for easy cleaning and maintenance
- No daily gas calibration required
Q-NRG
The New Generation Metabolic Monitor for Resting Energy Expenditure in spontaneously breathing subjects
- Resting Energy Expenditure in spontaneously breathing subjects
- Full Metabolic Assessment (REE, VO2, VCO2, VE, RQ etc.)
- Compact, lightweight, battery and main operated
- Test subjects with Canopy or (optional) Face Mask
- Immediate, simple set-up and system operation
- Designed for easy cleaning and maintenance
- No daily gas calibration required
TEST MODES
Vent (Mechanically assisted patients)
- Measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), together with other ventilatory parameters, and metabolism substrate utilization (%FAT, %PRO, %CHO).
- Ventilated patients (>age 10).
- Disposable PNT flowmeter (Flow-REE) inserted at the patient’s circuit
- All parts are single patient, no need for cleaning and disinfecting
- Independent from type of ventilator in use
[Available standard for Q-NRG+ only]
Canopy (Spontaneously breathing subjects)
- Measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), together with other ventilatory parameters, and metabolism substrate utilization (%FAT, %PRO, %CHO).
- Spontaneously breathing subjects (>age 6).
- Dilution technique using bubble canopy hood (available either adult or pediatric).
- Consumables: Canopy veil, antibacterial filters and corrugated tube
- Integrated canopy blower pump inside the unit (selectable flow rate with Q-NRG monitor).
[Available standard for Q-NRG and as an option for Q-NRG+]
Mask (Spontaneously breathing subjects)
- Measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), together with other ventilatory parameters, and metabolism substrate utilization (%FAT, %PRO, %CHO).
- Spontaneously breathing subjects (>age 6).
- External multi-use turbine flowmeter
- Multi-use silicone face masks with headgear for comfortable leak-free measurements
- 5 mask sizes (3 Adult and 2 Pediatric)
- Easy to clean and sterilize
[Available as an option for Q-NRG+ and Q-NRG]
TECH SPECS
| HARDWARE | |
|---|---|
| O2 gas analyser | Galvanic Fuel Cell (GFC) |
| CO2 gas analyser | Digital NDIR |
| Flowmeter - Vent | Disposable Pneumotach (Flow-REE) |
| Flowmeter - Canopy/Mask | Bidirectional digital turbine |
| Display | 10.1” Transmissive TFT LCD, 1024x600, 65k colors, capacitive touch screen |
| Battery Power | Battery: Li-Ion “smart”(3 hours autonomy) Mains: 100V-240V ±10%; 50/60Hz, 100-130 VA |
| Wireless connectivity | Bluetooth (2.1 + EDR Class II - Range 10 m line-of-sight) |
| Wired connectivity | 1 USB-device (5 kV galvanic insulated), 2 x USB Host, RS-232 (5 kV galvanic insulated), LAN (5 kV galvanic insulated) |
| Electrical requirements | 100-240V ± 10% 50/60 Hz |
| SOFTWARE (OPTIONAL) | |
| Software Interface | OMNIA |
| OS Compatibility | Windows 7, 8, 10 |
| Languages | Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Turkish, Russian, Chinese (Traditional & Simplifi ed), Korean, Romanian, Polish, Czech, Norwegian, Hebrew (interpretation only) |
To contact COSMED about COSMED Metabolic Monitor | Q-NRG+ use Get a quote.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Q-NRG max metabolic monitor
Metabolic Monitor | Q-NRG
PC-Based Spirometer | microQuark
Resmon Pro Full
MADA Antibacterial/viral spirometry and pulmonary function filter
Body Plethysmography | Q-Box
Antiviral/antibacterial respiratory filters
Resmon First FOT
Pulmonary Function Testing System | Quark PFT
Infant Body Composition Analyser | PEA POD
Bikes | Ergometers
INNOCOR CO - Cardiac Output Measurement
High quality Treadmill Machine
Face masks for metabolic testing
OMNIA Connector
Hand Held Spirometer | Spiropalm 6MWT
Indirect calorimeter - Quark RMR
Wearable Metabolic System - K5
INNOCOR LCI - Lung Clearance Index
Metabolic Monitor | Q-NRG+
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
